11.. . APPENDIX C: HYPERWARE FILE LISTING
USING THE OMP-MODL 11-109
APPENDIX B: EXAMPLE PROGRAM NETS
Following are some example Program Nets with descriptions of their operation.
Engine Oil Cooler Performance Test:
Two thermocouples are configured to sample inlet and outlet oil temperatures every
30 seconds on a heat exchanger. Logging of data only occurs when the engine
ignition is ON. The state of the ignition is checked every second via the 1 second
Sample Rate Clock and the GPDI input configured as an Event input.
When the inlet and outlet temperatures are enabled, a delta-T calculation is
performed and the inlet, outlet, and differential temperature is stored to memory.
Probe icons are available for display of all three temperatures from the LCD and/or
via a serial link.