Omega Vehicle Security TCIC Uživatelský manuál Strana 35

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 44
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 34
TCIC User’s Manual
33
One Card System
When a system includes only one card, neither configuration nor
selection is required, as the card is factory defaulted to address ‘a’.
Indeed, if a card has been configured to some non-‘a’ address and
later it is required as a single card, you may re-configure it to
address ‘a’, eliminating the need for the selection function in your
application. This is the only case that a card is configured to
address ‘a’.
Configuring a Card Address
Configuring a card address is carried out by the TCIC-Monitor
utility:
Connect the card to be configured to the USB port.
In the TCIC-Monitor utility click Setup/Card Address and
choose the required address. Be sure to choose a free
and non-‘a’ address; that is, an address that no other
card is configured to, but not ‘a’.
Exit the TCIC-Monitor utility.
The card is now ready to be wired into an RS485 network.
When it is powered on, it will not be selected until a
selection command with the correct address is sent by the
application.
It is the
user’s responsibility
to make sure that each
card is configured to a unique, non-‘a’, address.
Zobrazit stránku 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 43 44

Komentáře k této Příručce

Žádné komentáře